Naksha Techno Fiber

Welcome to Naksha Techno Fiber

Search

Nylon & PP Concrete Fibers – Complete Reinforcement Solution

Advanced Synthetic Macro & Micro Fibers for Crack-Resistant Concrete. NAKSHA TECHNO FIBER’s Nylon 6/6 and Polypropylene (PP) concrete fibers deliver superior crack control, impact resistance, and durability in residential, industrial, and infrastructure projects. Chopped lengths 6–60 mm. Engineered fibrillation and collating ensure optimal 3D dispersion. ASTM C1116, EN 14889, BIS IS 1835 compliant. Ahmedabad-manufactured precision.
ASTM C1116
EN 14889
BIS IS 1835
Concrete Reinforcement

Fiber Technology

PP: Micro-Fibrillating

Micro-fibrillating for plastic shrinkage control.

Nylon: Collated Bundles

High-tenacity collated bundles for structural reinforcement.

Dosage Efficiency

0.5–2.0 kg/m³ (PP), 3–15 kg/m³ (Nylon).

Bonding

Surface texturing for 200–400% cement matrix grip.

Complete Specifications

Two fiber types engineered for different reinforcement needs.

Polypropylene (PP) Fibers

Primary/secondary reinforcement for shrinkage & temperature cracks.
Property Specification Test Method Concrete Benefit
Diameter 0.3–1.2 mm Laser micrometer Micro-reinforcement
Length 6, 12, 19, 38, 54 mm Caliper Custom crack arrest
Tensile Strength 450–680 MPa ASTM C1557 Shrinkage resistance
Elongation 20–40% ASTM D638 Energy absorption
Aspect Ratio 40–150 L/D calculation Dispersion optimization
Fibrillation 3–12 petals Optical microscopy 3D matrix integration
Dispersion <5% clumps (pan mixer) ASTM C1735 Uniform performance
Alkali Resistance pH 13+ / 28 days: >90% strength ASTM D570 Long-term durability
Specific Gravity 0.91 ASTM D792 No settlement/ball-in-gut
Dosage 0.5–1.8 kg/m³ ACI 544.1R Cost-effective

Nylon 6/6 Fibers

Structural macro-fibers for impact, seismic, and fatigue resistance.
Property Specification Test Method Concrete Benefit
Diameter 0.15–0.9 mm Laser micrometer High aspect ratio
Length 20, 30, 40, 50, 60 mm Caliper Post-crack control
Tensile Strength 680–1,050 MPa ASTM C1557 Ultimate toughness
Elongation 25–55% ASTM D638 Ductility enhancement
Aspect Ratio 50–300 L/D calculation Maximum reinforcement
Collating 3–12 filaments/bundle Visual/microscopy Balling prevention
Flexural Toughness JCI >30 kJ/m² ASTM C1609 Residual strength
Impact 15–25x plain ACI 544.2R drop Accident-proof
Alkali Resistance pH 13+ / 28 days: >90% strength ASTM D570 Long-term durability
Specific Gravity 1.14 ASTM D792 Stable suspension
Dosage 3–15 kg/m³ EN 14889 Steel replacement

Performance Data & Mix Design

Comparative performance improvements vs. plain concrete.

PP vs. Nylon Fiber Performance Comparison

Test Method PP Fiber Result Nylon Fiber Result Improvement vs. Plain Concrete
Crack Width <0.3 mm (ASTM C1581) <0.2 mm 70–90% reduction
Residual Flexural 2.5–4.0 MPa (C1609) 5.0–8.0 MPa 300–600% increase
Shrinkage 40–60% less 30–50% less Plastic crack elimination
Freeze-Thaw >300 cycles (ASTM C666) >500 cycles Durability boost

Packaging & Sustainability

Formats

20–25 kg water-soluble bags, 1 MT bulk sacks.

Storage

2 years, dry conditions.

Eco

100% synthetic recyclable, reduces steel by 80%, lowers CO₂ footprint.
Scroll to Top